MC3 3000 Loss-In-Weight Controller

Specifications | Manual

The MC3 3000 Controller is designed to deliver material into a downstream process at a designed feedrate. MC Cubed Touch Screen Controller
Theory of OperationAn analog signal is used by the MC3 Controller to control the speed of a feeding device. The analog signal is varied by the controller to maintain a set feedrate. A Load Cell signal is monitored by the controller and is used as feedback for maintaining feedrate and totalizing the material fed from the feeder. The Load Cell signal is also used to determine when the feeder hopper requires material. An output from the MC3 Controller can control a refill device or can be used to signal another intelligent device that a refill is required. When the weight of material in the hopper reaches the correct level, the controller will remove the requirement for refill. This automatic function can be disabled for manual refill.

Process Values displayed include:

  • Feedrate
  • Net Weight
  • Feedrate Setpoint
  • Master Total
  • Sub-Total


Status Indicators Include:

  • Controller State
  • Run Permission
  • Stability
  • Feedrate State
  • Date
  • Time


Operator settable parameters include but are not limited to:

  • Feedrate Setpoint
  • Hopper (Refill) Parameters
  • Feedrate Limits
  • Setpoint Mode

Communication Interfaces:

  • Merrick Serial Communications Protocol
  • Modbus ASCII, Modbus +
  • DeviceNET, ControlNET
  • DF1, Data Highway +
  • Profibus
  • EtherNet


Standard Inputs and Outputs include:

  • Seven (7) Digital Outputs
  • Four (4) Digital Inputs
  • Two (2) Analog Outputs
  • One (10) Analog Input
  • DC Pulse Output for Totalizer


Maximum Inputs and Outputs available:

  • Fourteen (14) Digital Outputs
  • Eight (8) Digital Inputs
  • Four (4) Analog Outputs
  • One (1) Analog Inputs

Logical Digital Inputs and Outputs

Each physical Digital Input and Digital Output can be assigned (mapped to) a Logical I/O Function. In addition, the normal state of the input or output can be assigned such as normally open/closed, inverted or forced on/off.

Commonly used Logical Digital Inputs included but are not limited to:

  • Run Permission
  • Feeder Block
  • Start Refill
  • Stop Refill
  • Request Print

Commonly used Logical Digital Outputs included but are not limited to:

  • Refill Required
  • Feeder Running
  • General Alarm
  • High Weight
  • Low Weight
  • Empty Hopper
  • High Feedrate
  • Low Feedrate
  • In Control

MC3 3000 Loss-In-Weight Controller